WaterMax
DESCRIPTION
Premium self-cleaning water filter and softener for whole house water treatment. Has additional multi-compartment media tank to provide higher resin capacity and address more water problems. Has easy and efficient regeneration process.
- Water treatment flexibility
Additional compartment for adsorbent allows to address more specific water problems. - Bacteriostatic properties
Self-cleaning Bacteriostat prevents proliferation of bacteria in the resin bed. - No replacement filters
Filter life is renewed by simple and efficient Backwash and resin regeneration. - Safe and reliable
Safety shut-off system prevents water overflow.
| 53MAQ | 53BEQ (a) | 53MXQ | 53MDQ | 52AMQ (a) | 52APQ (b,c) | 52AKQ | 52AJQ (d) | |
|---|---|---|---|---|---|---|---|---|
| Footprint (WxD) | two units - 38,1 x 38,1 cm each | |||||||
| Height (H) | 98 cm | |||||||
| Weight | 40,5 | 45,6 | 50,4 | 45,6 | 42 | 50,1 | 48 | 54 |
| Temperature | 5 - 40 C | |||||||
| Drain Line (Minimum I.D.) | 1/2" | |||||||
| Salt storage capacity | 90 L | |||||||
| Power 12 VAC, 50Hz | Iron reduction to 0.3 ppm or less | |||||||
| Max Compensated Hardness (mg/L*) | 31 | 31 | 38 | 31 | 31 | 31 | 31 | 21 |
| Iron (ppm)5 ferrous | 0 | 0 | 12 | 0 | 12 | 2-12(b) | 15 | 5 |
| Minimum pH (standard units) | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 6,3 |
| Tannin (ppm) | 0 | 0 | 0 | 0-2 | 0 | 0 | 0 | 0 |
| Sulfur (ppm) | 0 | 0 | 0 | 0 | 0 | 0-57 | 0 | 0 |
| Maximum Chlorine (ppm) | 1 | 3 | 0 | 0 | 0 | 0 | 0 | 0 |
| Filtration-nominal rating (microns) | 20 | 25 | 20 | 20 | 20 | 20 | 20 | 20 |
| Media Amount Compartment #18 | 0.46 kg | 0.61 kg | 0.46 kg | 0.46 kg | Empty | Empty | Empty | Empty |
| Media Amount Compartment #28 | Empty | 11 L | 17 L | 8.5 L | 1.8 kg | 8.3 kg | 11 L | 11 L |
| Media Amount Compartment #3 Fine Mesh Cation Resin | 30 L | 30 L | 30 L | 30 L | 30 L | 30 L | 30 L | 30 L |
| Water Pressure (min–max, psi) | 20-120 | 20-120 | 20-120 | 20-120 | 20-120 | 20-120 | 30-120 | 20-120 |
| Brine Line Flow Control Refill (m3/h) | 0,11 | 0,11 | 0,11 | 0,11 | 0,11 | 0,11 | 0,11 | 0,11 |
| Flow Rate at 25 psi drop | 4.4 | 4.4 | 3.8 | 3.8 | 5.2 | 4.4 | 4.4 | 4.6 |
| Flow Rate at 15 psi drop | 2.49 | 2.95 | 2.38 | 2.38 | 2.54 | 2.4 | 2.4 | 2.83 |
| Pressure Drop @ Service Flow Rate of 0,91 (m3/h) | 6,47 psi | 8,38 psi | 8,38 psi | 8,38 psi | 3,09 psi | 5,88 psi | 5,88 psi | 6,91 psi |
| #1 Setting—18870 mg per 1 kg of salt. Salt kg/resin capacity mg | 0.3/ |
0.3/ |
0.48/ |
NA | 0.3/ |
NA | NA | NA |
| #2 Setting—16655 mg per 1 kg of salt. Salt kg/resin capacity mg | 0.84/ |
0.84/ |
1.3/ |
NA | 0.84/ |
NA | NA | 0.84/ |
| #3 Setting—15093 mg per 1 kg of salt. Salt kg/resin capacity mg | 1.6/ |
1.6/ |
2.9/ |
1.6/ |
1.6/ |
1.6/ |
1.6/ |
1.6/ |
| #4 Setting—12348 mg per 1 kg of salt. Salt kg/resin capacity mg | 2.8/ |
2.8/ |
4.4/ |
3.3/ |
2.8/ |
2.8/ |
2.8/ |
2.8/ |
| #1 Salt Setting—Total length of reg. Minutes/Liters | 12/ |
12/ |
12/ |
------ | 12/ |
----- | ----- | ----- |
| #2 Salt Setting—Total length of reg. Minutes/Liters | 18/ |
18/ |
26/ |
----- | 18/ |
----- | ----- | 23/ |
| #3 Salt Setting—Total length of reg. Minutes/Liters | 38/ |
38/ |
58/ |
47/ |
38/ |
44/ |
44/ |
44/ |
| #4 Salt Setting—Total length of reg. Minutes/Liters | 56/ |
56/ |
74/ |
64/ |
58/ |
61/ |
61/ |
61/ |
| Shipping weight (lb) | 40,5 | 45,6 | 50,4 | 45,6 | 42 | 50,1 | 48 | 54 |
| Bacteriostatic |
Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
- Municipally supplied chlorinated water only.
- Water should contain not less than 2 mg / L iron and 200 mg / L TDS.
- This model has no backwash flow control button or retainer. Must have a minimum of flow rate of 26.5 L / min at pressure of at least 2 atm.
- Calcite for pH normalization will add additional hardness to water before softening.
- Rate of flow must be verified at the end of 1/2" I.D. drain line.
- Any hardness over 3.5 mg/L will increase the chance of calcium carbonate precipitation. As the hardness increases so does the chance of this precipitation. Must use citric acid to regenerate along with salt.