WaterMax

harshness1
iron
color
type of water
type of water
 

Check your water concerns.

close 
 

DESCRIPTION

Premium self-cleaning water filter and softener for whole house water treatment. Has additional multi-compartment media tank to provide higher resin capacity and address more water problems. Has easy and efficient regeneration process.

 

  • Water treatment flexibility
    Additional compartment for adsorbent allows to address more specific water problems.
  • Bacteriostatic properties
    Self-cleaning Bacteriostat prevents proliferation of bacteria in the resin bed.
  • No replacement filters
    Filter life is renewed by simple and efficient Backwash and resin regeneration.
  • Safe and reliable
    Safety shut-off system prevents water overflow.
 
  53MAQ 53BEQ (a) 53MXQ 53MDQ 52AMQ (a) 52APQ (b,c) 52AKQ 52AJQ (d)
Footprint (WxD) two units - 38,1 x 38,1 cm each
Height (H) 98 cm
Weight 40,5 45,6 50,4 45,6 42 50,1 48 54
Temperature 5 - 40 C
Drain Line (Minimum I.D.) 1/2"
Salt storage capacity 90 L
Power 12 VAC, 50Hz Iron reduction to 0.3 ppm or less
Max Compensated Hardness (mg/L*) 31 31 38 31 31 31 31 21
Iron (ppm)5 ferrous 0 0 12 0 12 2-12(b) 15 5
Minimum pH (standard units) 7 7 7 7 7 7 7 6,3
Tannin (ppm) 0 0 0 0-2 0 0 0 0
Sulfur (ppm) 0 0 0 0 0 0-57 0 0
Maximum Chlorine (ppm) 1 3 0 0 0 0 0 0
Filtration-nominal rating (microns) 20 25 20 20 20 20 20 20
Media Amount Compartment #18 0.46 kg 0.61 kg 0.46 kg 0.46 kg Empty Empty Empty Empty
Media Amount Compartment #28 Empty 11 L 17 L 8.5 L 1.8 kg 8.3 kg 11 L 11 L
Media Amount Compartment #3 Fine Mesh Cation Resin 30 L 30 L 30 L 30 L 30 L 30 L 30 L 30 L
Water Pressure (min–max, psi) 20-120 20-120 20-120 20-120 20-120 20-120 30-120 20-120
Brine Line Flow Control Refill (m3/h) 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11
Flow Rate at 25 psi drop 4.4 4.4 3.8 3.8 5.2 4.4 4.4 4.6
Flow Rate at 15 psi drop 2.49 2.95 2.38 2.38 2.54 2.4 2.4 2.83
Pressure Drop @ Service Flow Rate of 0,91 (m3/h) 6,47 psi 8,38 psi 8,38 psi 8,38 psi 3,09 psi 5,88 psi 5,88 psi 6,91 psi
#1 Setting—18870 mg per 1 kg of salt. Salt kg/resin capacity mg 0.3/5850 0.3/5850 0.48/9360 NA 0.3/5,850 NA NA NA
#2 Setting—16655 mg per 1 kg of salt. Salt kg/resin capacity mg 0.84/13890 0.84/13890 1.3/21680 NA 0.84/13890 NA NA 0.84/13890
#3 Setting—15093 mg per 1 kg of salt. Salt kg/resin capacity mg 1.6/28730 1.6/28730 2.9/44840 1.6/28730 1.6/28730 1.6/28730 1.6/28730 1.6/28730
#4 Setting—12348 mg per 1 kg of salt. Salt kg/resin capacity mg 2.8/35300 2.8/35300 4.4/55090 3.3/35300 2.8/35300 2.8/35300 2.8/35300 2.8/35300
#1 Salt Setting—Total length of reg. Minutes/Liters 12/51,09 12/60,56 12/51,09 ------ 12/90,84 ----- ----- -----
#2 Salt Setting—Total length of reg. Minutes/Liters 18/62,45 18/71,91 26/77,59 ----- 18/102,19 ----- ----- 23/264,95
#3 Salt Setting—Total length of reg. Minutes/Liters 38/100,3 38/111,65 58/138,15 47/117,33 38/140,04 44/302,8 44/302,8 44/302,8
#4 Salt Setting—Total length of reg. Minutes/Liters 56/134,36 56/143,83 74/168,43 64/149,5 58/211,96 61/336,86 61/336,86 61/336,86
Shipping weight (lb) 40,5 45,6 50,4 45,6 42 50,1 48 54
Bacteriostatic-KDF® Process Media* Yes Yes Yes Yes Yes Yes Yes Yes
  1. Municipally supplied chlorinated water only.
  2. Water should contain not less than 2 mg / L iron and 200 mg / L TDS.
  3. This model has no backwash flow control button or retainer. Must have a minimum of flow rate of 26.5 L / min at pressure of at least 2 atm.
  4. Calcite for pH normalization will add additional hardness to water before softening.
  5. Rate of flow must be verified at the end of 1/2" I.D. drain line.
  6. Any hardness over 3.5 mg/L will increase the chance of calcium carbonate precipitation. As the hardness increases so does the chance of this precipitation. Must use citric acid to regenerate along with salt.